Page 76 - Studia Universitatis Hereditati, vol 12(2) (2024)
P. 76

Table 5. The Area Covered by the Sound of Bells (km ) Shown per Sound Levels (dB)
                                                     2
                                                                                 2
                                                                     Coverage area (km ) by the sound levels
                #    General description of weather conditions
                                                               05-15 dB 15-30 dB 30-45 dB 45-60 dB 60-90 dB  Total
                A.1.  As measured onsite (no wind)                7.12   7.9   1.17  0.28  0.0285  16.49
                A.2.  As measured onsite, but with the most favorable wind conditions  3.56  1.49  0.21  0.04  0.0157  5.32
                B.1.  Extremely cold and calm winter day          6.57  6.08  0.89  0.24  0.0271  13.8
                B.2.  Extremely cold and windy winter day         2.48  0.95   0.18  0.02  0.0054  3.64
                C.1.  Extremely hot and calm summer day           4.97  4.53   0.8   0.22  0.0263  10.55
                C.2.  Extremely hot and windy summer day          1.88  0.97  0.17  0.02   0.005  3.04

               spectively) at a level between 15 and 30 dB un-  propagation area is shrunk by 3 to 4 times (tab.
        76     der no-wind conditions. In contrast, the church   5). Only in scenario A.2., which includes the ‘fa-
               Sant Andreu de València d’Àneu (number 10 on   vorable wind’ blowing from the church San-
        studia universitatis hereditati, letnik 12 (2024), številka 2 / volume 12 (2024), number 2
               the map) is on the border area in scenarios A.1.   ta Maria d’Àneu towards the village Esterri
               and B.1.                                    d’Àneu, does the bell sound reach the church-
                   The scenarios that include wind are pre-  es Sant Vicenç d’Esterri d’Àneu and Sant Martí
               sented in the right column (fig. 6, A.2., B.2., and   d’Escalarre (numbers 12 and 14 on the map, re-
               C.2.). When the wind is introduced, the sound   spectively) at a level between 5 and 15 dB. In B.2.,







































               Figure 7: Individual Viewshed from Santa Maria d’Àneu
   71   72   73   74   75   76   77   78   79   80   81